Attic frost concentrated around an unsealed access hatch

The frost distribution followed the warm-air leakage plume rather than the roof covering or outdoor wind direction.

Measurement Supportedrecorded confirmation level
01 / OBSERVED

Frost on roof sheathing above the attic hatch

02 / CONFIRMED CAUSE

Warm indoor air leaking through the attic hatch

03 / REPAIR

The hatch was weather-stripped, insulated and latched evenly.

04 / VERIFY

No new frost plume formed during a later cold spell.

WHAT CHANGED THE DIRECTION

The evidence that separated the cause

Supporting clues

  1. Frost plume centered on hatch
  2. Higher attic humidity after occupancy
  3. Roof exterior remained intact

Checks performed

  1. Smoke-pencil test
  2. Infrared comparison
  3. Attic humidity log
Field lessonThe shape of frost can map the air pathway.