STRUCTURED EVIDENCE SESSION

Attic frost: source opening versus frost field

Map frost before thaw, then compare the frost field with ceiling penetrations, exhaust routes and the coldest roof surfaces.

Browser-local draftNo session answers are sent to the server. Evidence balanceScores organize observations; they are not probabilities. No repair authorizationStop signals override the ordinary workflow.
01
Freeze the evidence

Record the condition before interpreting it.

02
Evidence ledger

Mark what raises or weakens each route.

Leave unknown items unmarked. Contradictory observations are useful evidence.

1

Interior air leakage through a ceiling bypass

Warm moist indoor air enters the attic through a penetration and spreads before freezing.

0
Raises fit +2 each
Lowers fit −2 each
2

Bathroom or dryer exhaust discharging into the attic

A fan or duct releases concentrated moisture directly into the roof space.

0
Raises fit +2 each
Lowers fit −2 each
3

Roof-space ventilation imbalance

Poor air distribution keeps some roof surfaces colder or wetter and amplifies another moisture source.

0
Raises fit +2 each
Lowers fit −2 each
03
Decision points

Change one condition at a time.

An answer changes investigation order; it does not prove a concealed condition.

1

Is there a concentrated frost plume at an exhaust duct or fan route?

If yes: Treat the exhaust connection as a priority defect.

If no: Map ceiling bypasses and pressure-driven air leakage.

2

Does the frost field align with one cold or poorly ventilated roof zone?

If yes: Assess ventilation distribution as an amplifier, not automatically the original source.

If no: Focus on the moisture entry route and indoor humidity load.

Safety interlock

Stop signals override scoring.

Mark the stop state when any listed boundary is present. Do not create a better clue by increasing exposure.

  • Do not enter an attic with unsafe access, damaged framing or exposed electrical hazards.
  • Do not disturb suspect insulation or vermiculite without material identification.
05
Current conclusion

Explain what changed the ranking.