Guided evidence worksheet

Shower leak paths: splash, drain, supply and waterproofing

Change one condition at a time: supply pressure, drain loading, spray location and standing water. Record the delay to the first leak.

Shower leak paths: splash, drain, supply and waterproofingSeparate four overlapping shower-related routes by changing one operating condition at a time. Original explanatory diagram, not a site photograph.
Reasoning guardrail

Separate the routes before choosing a repair.

A wet ceiling below the shower does not identify whether the drain, supply or waterproofing failed.

Trigger
Leak timing during spray, standing water and fixture use is the strongest separator.
Area
Bathroom
Provenance
Original explanatory diagram, not a site photograph.
1. Freeze the evidence

What happened first?

2. Competing hypotheses

Record evidence for and against each route.

1

Pressurized supply or valve leak

A fitting or supply route leaks while the valve is open, even when water does not reach the drain.

Evidence that raises fit
Evidence that lowers fit
Notes
2

Drain body or waste connection leak

Water escapes when the drain or trap receives flow or standing water.

Evidence that raises fit
Evidence that lowers fit
Notes
3

Waterproofing transition or splash escape

Water crosses a wall, curb, door or penetration boundary during spray exposure.

Evidence that raises fit
Evidence that lowers fit
Notes
3. Decision points

Change one condition at a time.

1

Does the leak occur with the valve on while water is captured before it reaches surfaces and drain?

Yes: Move pressurized supply components to the front.

No: Separate drain loading from spray exposure.

Observed answer and evidence
2

Does a drain-only test reproduce the leak?

Yes: Prioritize drain body, trap and waste connections.

No: Map spray direction, curb and waterproofing transitions.

Observed answer and evidence
4. Smallest safe checks

Plan the next observation.

1

Change one condition

Separate spray location, drain loading and supply pressure instead of repeating a full shower.

2

Protect electrical areas

Stop testing if water approaches lights, wiring or energized equipment.

3

Document delay

A delayed drip can indicate storage within the assembly.

Safety boundary

Stop rather than create a better clue.

  • Stop testing if water approaches lights, wiring or an occupied ceiling cavity.
  • Do not perform repeated flooding tests that can increase concealed damage.
5. Current conclusion

What changed the ranking?